The concealed path between the dryer and the outside wall. This is where lint actually collects and where most of the fire risk lives, so everything here is rigid metal with a smooth interior — nothing corrugated, nothing plastic, nothing that gives lint a ridge to catch on.

Duct Run & Fittings

On the counter now

No prices are listed — every part is quoted after a fit check confirms the inspection finding it answers. Anchor components open a full page; boxed code parts and accessories are listed here.

02

Premium grade

Rigid Aluminum Duct (4-inch)

Same smooth-wall requirement as galvanized, lighter to work with, and the one we reach for on reroutes through finished space where the run has to be handled a lot before it is fastened. It meets the same code rules; the choice between the two is usually about the install, not the performance.

Diameter: 4" nominal (IRC M1502.4.1)Interior: Smooth wall

Listed part · ask in your quoteQuote
03

Code part / accessory

Adjustable Metal Elbow

Every bend costs you length. Code counts a 90-degree bend as five feet of your allowance and a 45 as two and a half, so on a long run the difference between two elbows and four is the difference between a duct that clears and a duct that never will. We use adjustable elbows to hold the angle we actually need instead of forcing the run to fit stock fittings.

Length penalty: 90° counts as 5 ft, 45° as 2.5 ft (IRC M1502.4.5.1)

Listed part · ask in your quoteQuote
05

Code part / accessory

Periscope (Close-Clearance) Vent

A flat telescoping section that lets the dryer sit almost against the wall when the wall outlet and the appliance outlet do not line up. Honest limitation: a periscope is a fixed offset, so it only works when the two openings are genuinely close. If they are far apart or on different planes, a recessed box or a reroute is the right call and we will say so rather than force it.

Fit: Requires wall and appliance outlets in close alignment

Listed part · ask in your quoteQuote
06

Code part / accessory

Wall & Floor Penetration Thimble

The sleeve that carries the duct through a framed wall or floor cleanly, holds the run centred, and keeps the penetration sealed. Small part, and the one that gets skipped most often on rushed installs — which is how you end up with a duct resting on a joist edge and slowly wearing a hole in itself.

Listed part · ask in your quoteQuote
07

Code part / accessory

Foil Tape Joint Sealing

How the joints actually get sealed, because the obvious method is the prohibited one. Code does not allow fasteners that extend into the duct, so every joint on a run we build is taped rather than screwed. Cloth duct tape is not a substitute here — it dries out, releases, and the joint opens up inside the wall where nobody sees it.

Why not screws: Fasteners may not extend into the duct (IRC M1502.4.3)

Listed part · ask in your quoteQuote
08

Premium grade

Insulated Sleeve for Attic Runs

For the stretch of duct that crosses an unconditioned attic. Hot wet dryer air hitting cold metal condenses, the water runs back down the duct, and the lint it soaks turns into a paste that no amount of brushing shifts. Insulating that stretch is the fix. If your run crosses an attic in an unheated space and it has never been sleeved, this is worth looking at before the next cleaning.

Applies to: Duct passing through unconditioned space

Listed part · ask in your quoteQuote

More sizes & variants available — name your duct size or dryer model in your quote request

15+
Years in the field
IRC M1502
Checklist
48h
Written report
< 2hr
Response
Ready when you are

Get it inspected. Get it in writing.

Flat fee confirmed when you book. Same-week scheduling. A pass/fail verdict within 48 hours.

Licensed & Insured Same-Week Scheduling Photo-Documented Findings
Emergency

24/7 Response

No airflow, overheating dryer, burning smell, or a vent you're not sure about? We answer 7 AM to midnight and the assessment ends in a written safe-to-use verdict — including a do-not-use notice when the evidence supports one. After-hours dispatch runs subject to crew availability.

Emergency line
Call NowBook